Oil separators are used to separate out oil from waste water and storm water into the local network.
Density factor allows differing densities for light liquids.
Densitet (g/cm3) | |||
---|---|---|---|
<= 0,85 | 0,85 - 0,90 | 0,9 - 0,95 | |
Combination | Density factor | ||
S-II-P | 1 | 2 | 3 |
S-I-P | 1 | 1,5 | 2 |
S-II-I-P | 1 | 1 | 1 |
Combiantion | |
---|---|
Components | Designation |
Sludge seperator | S |
Seperator class I | I |
Seperator class II | II |
Testing well | P |
A class I separators cleaner to a higher degree than a class II separators. Below are some examples of combinations.
Application | Combination |
---|---|
Storm water from petrol stations, car parks, road, etc. | S-II-P |
Cleaning with cleaning agents (spills and leaks) in workshops. | S-I-P |
Cleaning without cleaning agents (spills and leaks) in workshops. | S-II-P |
Manually vehicle wash | S-P |
Automatic vehicle washing | S-II-P |
Obstacle factor | |
---|---|
0 | Oil-contaminated stormwater from paved surfaces. |
1 | For the leakage of light mineral oils and protect the surrounding area. |
2 | Wastewater from industrial processes, vehicle washing, cleaning of oil-covered split etc. |
Nominal size the calculated value is used to select the appropriate size of an oil separator.
Is the largest sewagewater flow from the actual plant that reaches oil separator.
Is the largest stormwater flow from the actual plant that reaches oil separator.
It refers to the size of the chamber in the oil separator that handles the sludge that comes with the wastewater.
Quantity | Example |
---|---|
None | Condensate |
Small | Processed wastewater sludge demonstrated little content. |
Runoff surfaces of precipitation where small amount of sludge from traffic etc. are encountered. | |
Medium | Minimum volume for sludge separation 600 l. |
Gas stations | |
Manunal vehicle washing or bus washing. | |
Wastewater from garages and parkinglots. | |
High | Minimum volume for sludge separation 600 l. |
Washing facilities for construction equipment, agricultural machinery and the like. | |
Wash locations for trucks. | |
Automatic car wash | The same calculation as for high sludge quantity but with a minimum volume of 5000 l. |
Nominal size: | |
---|---|
Sludge quantity small: | |
Sludge quantity medium: | |
Sludge quantity high: |